HAIYAN KANGYUAN MEDICAL INSTRUMENT CO., LTD.

Hot New Products Pvc Laryngeal Mask Airway - Laryngeal Mask Airway for Single Use – Kangyuan

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of endotracheal tube nasal factory , temperature sensing urethral catheter , stomach tube manufacturer , Our merchandise are widely recognized and dependable by users and can meet continuously building economic and social needs.
Hot New Products Pvc Laryngeal Mask Airway - Laryngeal Mask Airway for Single Use – Kangyuan Detail:

Laryngeal Mask Airway for Single Use

Packing: 5 pcs/box. 50 pcs/carton
Carton size: 60x40x28 cm

The product is suitable for use in patients who need general anesthesia and emergency resuscitation, or to establish short-term non deterministic artificial airway for patients who need breathing.

This product according to the structure can be divided into ordinary type, double strengthened type, ordinary type, double reinforced four types. The ordinary type ventilation tube, cover bag fittings, inflatable tube, indicating airbag, joint and inflatable valve; reinforced by ventilation tube, cover bag connector, an aeration pipe. Indication of the air guide rod, (can not), and joint charge valve; double ordinary type by the ventilation tube, drainage tube, cover bag fittings, inflatable tube, indicating airbag, joint and inflatable valve; double pipe reinforced by ventilation pipe, drainage pipe, cover bag fittings, inflatable tube, indicator the airbag, the connecting sleeve pad, guide rod (no), joint and a charge valve. Strengthen and double reinforced laryngeal mask on the inner wall of the trachea with stainless steel wire products. To strengthen the ventilation tube, drainage tube, cover bag connecting piece, the connecting sleeve pad, inflatable tube, air bag adopts instructions made of silicon rubber material. If the product is sterile; ring Oxygen ethane sterilization, ethylene oxide residues should be less than 10μg/g.

Model

Ordinary type, Reinforced type,
The ordinary type with double tube,
The reinforced type with double tube 

Specifications(#)

1

1.5

2

2.5

3

4

5

6

Maximum inflation(Ml)

4

6

8

12

20

30

40

50

Applicable patient / body weight(kg)

Neonatus<6

Baby6~10

Children10~20

Children20~30

Adult30~50

Adult50~70

Adult  70~100

Adult   >100

1. The LMA, should check with the specifications of product labeling.
2. To exhaust the gas in the airway of the laryngeal mask airway so that the hood is completely flat.
3. Apply a small amount of normal saline or water soluble gel for lubrication in the back of the throat cover.
4. The patient’s head was slightly back, with his left thumb into the patient’s mouth and traction of the patient’s jaw, in order to widen the gap between the mouth.
5. Using the right hand to hold the pen holding the laryngeal mask, to make available, the index finger and middle finger finger against the cover connection body and the ventilation tube laryngeal mask, cover the mouth towards the direction along the midline of lower jaw, tongue sticking down pharyngeal LMA, until no longer advance so far. Also can use reverse the method of inserting laryngeal mask, just cover the mouth toward the palate, will be placed in the mouth to the throat at the bottom of the laryngeal mask, and 180O after rotation, and then continue to push down the laryngeal mask, until can’t push so far. When using the enhanced or ProSeal laryngeal mask with guide rod, the guide rod can be inserted into the air cavity to reach the designated position, and the insertion of the laryngeal mask can be drawn out after the insertion of the laryngeal mask.
6. In the move before the other hand gently with finger pressing to prevent laryngeal mask airway catheter displacement.
7. According to the nominal charge to cover bag filled with gas (air amount can not exceed the maximum filling mark), connect the breathing circuit and assess whether good ventilation, such as ventilation or obstruction, should according to the steps of re insertion of laryngeal mask.
8. To confirm the position of the laryngeal mask is correct, cover the tooth pad, fixed position, maintain ventilation.
9. The throat cover is pulled out: the air behind the air valve of the syringe with the syringe without needle is pulled out of the throat cover.

1. Patients who were more likely to have a full stomach or stomach content, or who had a habit of vomiting and other patients who were prone to reflux.
2. Abnormal enlargement of the patient with bleeding in the respiratory tract.
3. The potential of respiratory tract obstruction patients, such as sore throat, abscess, haematoma etc.,
4. The patient is not suitable for the use of this product.

1. Before use should be based on age, body weight of different choice of the correct model specifications and detect whether the bag leak.
2. Please check before use, such as found in single (packaging) products have the following conditions, the prohibition of the use of:
a) Effective period of sterilization;
b) The product is damaged or has a foreign body.
3. Use should observe the patient thoracic activity and auscultation of bilateral breath sound to determine the ventilation effect and end expiratory carbon dioxide monitoring. Such as the discovery of thoracic or poor or non fluctuating amplitude fluctuations hear the leak sound, should immediately pull the laryngeal mask, after full oxygen again after implantation.
4. Positive pressure ventilation, airway pressure should not exceed 25cmH2O, or prone to leakage or gas into the stomach.
5. Patients with laryngeal mask should be fasting before use, in order to avoid the possibility of anti – flow induced aspiration of gastric contents during positive pressure ventilation.
6. This product is ethylene oxide sterilization, sterilization is valid for three years.
7. When the balloon is inflated, the amount of charge should not exceed the maximum rated capacity.
8. This product for clinical use, operation and use by medical personnel, after the destruction.

[Storage]
Products should be stored in relative humidity of not more than 80%, the temperature is not more than 40 degrees Celsius, no corrosive gases and good ventilation clean room.
[Date of manufacture] See inner packing label
[expiry date] See inner packing label
[Specification publication date or revision date]
Specification publication date : September 30, 2016

[Registered person]
Manufacturer: HAIYAN KANGYUAN MEDICAL INSTRUMENT CO., LTD


Product detail pictures:

Hot New Products Pvc Laryngeal Mask Airway - Laryngeal Mask Airway for Single Use  – Kangyuan detail pictures


Related Product Guide:

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Hot New Products Pvc Laryngeal Mask Airway - Laryngeal Mask Airway for Single Use – Kangyuan, The product will supply to all over the world, such as: Slovak Republic, Poland, Hyderabad, We take measure at any price to attain essentially the most up-to-date gear and procedures. The packing of nominated brand is our a further distinguishing feature. The solutions to assure years of trouble-free service has attracted a great deal customers. The goods are obtainable in improved designs and richer variety, they're produced scientifically of purely raw supplies. It accessible in a variety of designs and specifications for the selection. The newest forms are much far better than the previous one and they're extremely popular with several clients.
  • This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Edwina from Algeria - 2018.03.03 13:09
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Lorraine from Botswana - 2018.06.05 13:10

    Related Products