High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for 2 way foley catheter , Indwelling Catheter , tiemann tipped foley catheter , We sincerely welcome domestic and foreign merchants who calls, letters asking, or to plants to negotiate, we will offer you quality products and the most enthusiastic service,We look forward to your visit and your cooperation.
Special Design for 3 Way Balloon Catheter - Suprapubic Silicone Foley Catheter – Kangyuan Detail:

Suprapubic Silicone Foley Catheter Open Tipped with Integral Balloon Male Female
Made of 100% imported medical-garde silicone.
This product belongs to Class IIB.
Radio opaque line through the length fot x-ray visualization.
Soft and uniformly inflated balloon makes tube sit well against the bladder.
Special open-ended design, increase the volume of the drainage.
Color-coded check vavle for identification of different sizes.
Length of the Foley catheter: 400mm.

1

Packing: 10 pcs/box, 200 pcs/carton
Carton size: 52x35x25 cm

“KANGYUAN”Urinary Catheters for Single Use (Foley) is made of imported silicon rubber by advanced technology. The product has smooth surface, slight stimulation, large apocenosis volume, reliable balloon, convenient to use safely, multiple of types and specification for choice. 

This product is composed of urethral drainage catheter and temperature probe. Urethral drainage catheter consists of catheter body, balloon (water sac), guide head (tip), drainage lumen interface, filling lumen interface, temperature measuring lumen interface, flushing lumen interface (or no), flushing lumen plug (or no) and air valve. Temperature probe consists of temperature probe (thermal chip), plug interface and guide wire composition. Catheter for children(8Fr, 10Fr) can include a guide wire(optional). The catheter body, guide head (tip), balloon (water sac) and each lumen interface are made of silicone; the air valve is made of polycarbonate, ABS plastic and polypropylene; the flushing plug is made of PVC and polypropylene; the guide wire is made of PET plastic and temperature probe is made of PVC, fiber and metal material.

The product can be clinically used to urinate and douche urinary bladder by inserting into urinary bladder though urethra. 

1. Lubrication: Generously lubricate tip and shaft of the catheter before insert.

2. Insert: Carefully insert catheter tip into the bladder (normally indicated by urine flow), and then a further 3cm to ensure balloon is also inside it.

3. Inflating water: Using a syringe without needle, inflate balloon with sterile distilled water or 5%10% glycerin aqueous solution is supplied. Recommended volume to use is marked on funnel of catheter.

4. Extraction: For deflation , cut off the inflation funnel above the valve, or using a syringe without needle push into valve to facilitate drainage.

5. Dwell catheter: the dwelling time is as the requirement of clinic and nurse. 

The unsuitable condition considered by doctor. 

1. Do not use ointments or lubricants having a petroleum base.
2. Different specification of urethral catheter should be chose as different ages prior to use.
3. This product had been sterilized by ethylene oxide gas, and discard after single use.
4. If packing is damaged, do not use.
5. The size and balloon capacity is marked on outer unit pack and funnel of catheter.
6. The guide wire for the auxiliary intubation in the drainage channel of the catheter is pre placed in the children.
7. In use, such as the discovery of urinary catheter, urinary extravasation, inadequate drainage,
catheter replacement should be applicable specifications timely.
8. This product should be operated by medical staff.
9. Indwelling time recommend no more than 28 days.

[Warning]
The injection of sterile water shall not exceed the nominal capacity on the catheter (ml).

[Storage]
Store in a cool, dark and dry place, the temperature should not higher than 40℃, without corrosive gas and good ventilation.
[Date of manufacture] See inner packing label
[Expiry date] See inner packing label
[Registered person]
Manufacturer: HAIYAN KANGYUAN MEDICAL INSTRUMENT CO., LTD


Product detail pictures:

Special Design for 3 Way Balloon Catheter - Suprapubic Silicone Foley Catheter – Kangyuan detail pictures


Related Product Guide:

We now have a highly efficient crew to deal with inquiries from clients. Our intention is "100% shopper pleasure by our merchandise quality, price tag & our staff service" and take pleasure in a very good standing amongst purchasers. With quite a few factories, we can easily provide a wide vary of Special Design for 3 Way Balloon Catheter - Suprapubic Silicone Foley Catheter – Kangyuan, The product will supply to all over the world, such as: United Arab Emirates, UK, Germany, To create more creative products, maintain high-quality products and update not only our products but ourselves so as to keep us ahead of the world, and the last but most vital one: to make every client satisfied with everything we offer and to grow stronger together. To be the real winner, starts here!
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Marjorie from Manchester - 2017.11.01 17:04
    Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Ellen from Saudi Arabia - 2017.05.02 11:33

    Related Products